Septic
Soil Absorption System
- 5 feet from any lot line
- 10 feet from any water service or any building
- 15 feet from any swimming pool or any building
- 50 feet from any well, reservoir or from the ordinary high-water mark of any lake, stream or other navigable water
Septic/Holding Tank Setbacks
- 2 feet from any lot line
- 5 feet from any building or water service
- 25 feet from any well
- 10 feet from the ordinary high-water mark of any lake, stream or other water course
Note: Holding tanks shall be no further than 25 feet from a service access.
Minimum Tank Sizing Requirements | ||
Number of Bedrooms
|
Septic Tank Size (Gallons)
|
Holding Tank Size (Gallons)
|
1
|
313
|
2,000
|
2
|
626
|
2,000
|
3
|
940
|
2,000
|
4
|
1,253
|
2,500
|
5
|
1,566
|
3,000
|
6
|
1,877
|
3,500
|
9
1
2
2