All specifications herein set forth shall meet the minimum requirements of the following codes: Chapter 145.135, Wisconsin Statutes; Chapter NR 113.03(50): Comm Chapter 91 and Section 4.49 Sawyer County Zoning Ordinance.
Location:
Privies shall be located at a minimum horizontal distance of:
-
10 feet from any slab constructed accessory building (i.e., garage, shed, storage building etc.).
-
25 feet from any lot line.
-
25 feet from any habitable building.
-
25 feet from the edge of a 20% slope.
-
50 feet from any water supply well.
-
75 feet from navigable waters or watercourses.
-
Setback distances from highways and other roads are:
a. State and US numbered highways - 130 feet from the centerline or 66 feet form the right-of-way line, which ever is greater.
b. County Trunk highways - 75 feet from the centerline or 42 feet from the right-of-way line, which ever is greater.
c. Town roads - 63 feet from the centerline or 30 feet from the right-of-way line, which ever is greater.
d. Private access easements - 30 feet from the centerline.
General Requirements:
-
The privy building shall be insect and vermin proof.
-
Privies should be provided with a concrete floor and risers and the interior painted or paneled.
-
Privies should be provided with a suitable approach, such as concrete, gravel or cinder block.
-
All windows, ventilators, and other openings should be screened with 16 mesh screening to prevent entrance of insects
-
Privy doors should swing and be self-closing.
-
Privy seats should be provided with hinged covers.
-
The entire installation should be kept clean and sanitary. Freshly slaked lime or other equally effective disinfectants should be used at frequent intervals for odor control.
-
Floors, walls, seats and urinals should be scrubbed as often as possible.
-
The outer base of the privy should be banked with earth.
-
For open pit privies, the bottom of the pit shall be a minimum of three (3) feet above high groundwater or bedrock. A certified soil test and site evaluation is required for open pit privies. No soil test is required if a vault privy is installed. The soil test must be filed in the zoning office before permits will be issued.
-
Concrete or cement block foundation walls should extend six (6) inches above the ground and twelve (12) inches below the ground to prevent the entrance of insects and vermin.
-
It is suggested, but not mandatory, that the open pit privy be excavated to a five (5)feet depth and the pit be provided with a wood crib lining.
-
The vault privy shall have a water-tight vault and be constructed of welded steel, monolithic concrete, glass-fibre reinforced polyester or other materials approved by the Department of Commerce.
-
An exterior vermin-tight access opening for cleaning of the vault shall be provided where a water-tight vault has been installed.
-
Vault privies should be ventilated with a pipe of at least four (4) inches in diameter which terminates at least one foot above the roof of the privy and is provided with an effective ventilating hood.
-
The privy should be provided with cross ventilation equal to two (2) square feet of screened opening for each seat.
-
The vault privy should be cleaned/pumped out when nearly full by a licensed septic hauler.
-
According to Department of Commerce 91.12 Privies(1) the storage chamber of a vault privy shall have a minimum storage capacity of 200 gallons or one cubic yard.
Restrictions:
-
Under Chapter 83 WI Dept Comm, Private Sewage, any building containing a water closet, wash basin, kitchen sink, shower, bathtub, laundry facility, dishwasher, or other fixture receiving domestic waste, requires connection to an approved waste disposal system.
-
If a dwelling will include any type of indoor plumbing fixtures, a Sanitary Permit must be obtained prior to the issue of a Land Use Permit.
-
Size restrictions, footprint shall not exceed 6' x 6'maximum, maximum height 10' to peak of roof.
-
Privies shall not be used for storage.